Search
Power capacitors

multicond

Reactive power compensation components
multicond premium UHPC 10.0 25.0 37

The multicond power capacitors have been developed for reactive current compensation in 1-phase and 3-phase versions – specifically for the highest demands on safety and service life.

In addition to long life expectancy and high current and voltage carrying capacity, safety in the event of overload thanks to the all-pole overpressure cut-out is a decisive advantage of the compact power capacitors. Thanks to the dry technology construction of the components, good heat dissipation, low self-heating and reliable operation at high ambient temperatures are further advantages.

Depending on your requirements, you can obtain multicond power capacitors in different versions from basic to premium. Note: In networks with increased harmonic loads, we recommend the use of power capacitors from the multicond-premium series.

The power capacitors impress with the highest quality on the market, which we guarantee through our own development, production and testing at our factory in Schwabach in accordance with our “Made in Germany” quality promise.

Highlights
... premium UHPC, UHPC
... basic UHPC
... light UHPC
... Temperature classes
  • Outputs from 2.8 to 37 kvar
  • Capacitor rated voltage of 280, 415, 440, 480, 525, 690 or 800 V
  • High level of safety thanks to dry technology and 3-phase overpressure breakaway protection
  • Including compact discharge resistor
  • Long service life
Power capacitors “multicond premium UHPC” and “multicond UHPC”
Nominal voltage Un = 280, 415, 440, 480, 525, 690 or 800 V
Frequency 50/60 Hz
Maximum permissible operating voltage 1.0 xUn permanent
1.1 xUn for 8 hours/day
1.15 xUn for 30 minutes/day
1.2 xUn 200 x 5 minutes
1.3 xUn to 200 x 1 minute
Maximum permissible operating current 2.0 xIn
Maximum peak inrush current 400 xIn
Capacity tolerance + / – 5 %
Power loss < 0.20 W / kvar, without discharge resistors
Voltage test
(clamp – clamp)
2.15 x Unenn (AC), 10 sec
Voltage test
(terminal – housing)
≤ 690 V : 3600 V (AC), 2.5 sec
> 690 V : 6000 V (AC), 10 sec – according to standard
Cooling Self-cooling
Permissible humidity 95 %
Maximum insert height 4000 m above sea level
Installation location, installation position inside, any
Fastening M12 threaded bolt on the floor
Security features – Dry technology, resin-filled
– Self-healing
– All-pole overpressure shut-off protection
– SF6-free, PCB-free
Housing Aluminum
Protection class IP 20
Dielectric Polypropylene
Connection terminals Finger-safe, double-sided connection terminal
Discharge Discharge resistors external to the terminal
Standards IEC 60831-1 + 2, EN 60831-1 + 2,
VDE 0560-46 + 47
Power capacitors multicond basic UHPC
Nominal voltage Un = 280, 440, 480, 525, 690 or 800 V
Frequency 50/60 Hz
Maximum permissible operating voltage 1.0 xUn permanent
1.1 xUn for 8 hours/day
1.15 xUn for 30 minutes/day
1.2 xUn 200 x 5 minutes
1.3 xUn to 200 x 1 minute
Maximum permissible operating current 2.0 xIn
Maximum peak inrush current 400 xIn
Capacity tolerance + / – 5 %
Power loss < 0.20 W / kvar, without discharge resistors
Voltage test
(clamp – clamp)
2.15 x Unenn (AC), 10 sec
Voltage test
(terminal – housing)
≤ 690 V : 3600 V (AC), 2.5 sec
> 690 V : 6000 V (AC), 10 sec – according to standard
Cooling Self-cooling
Permissible humidity 95 %
Maximum insert height 4000 m above sea level
Installation location, installation position inside, any
Fastening M12 threaded bolt on the floor
Security features – Dry technology, resin-filled
– Self-healing
– All-pole overpressure shut-off protection
– SF6-free, PCB-free
Housing Aluminum
Protection class IP 20
Dielectric Polypropylene
Connection terminals Finger-safe, double-sided connection terminal
Discharge Discharge resistors external to the terminal
Standards IEC 60831-1 + 2, EN 60831-1 + 2,
VDE 0560-46 + 47
Power capacitors multicond light UHPC
Nominal voltage Un = 280, 440, 480, 525 or 690 V
Frequency 50/60 Hz
Maximum permissible operating voltage 1.0 xUn permanent
1.1 xUn for 8 hours/day
1.15 xUn for 30 minutes/day
1.2 xUn 200 x 5 minutes
1.3 xUn to 200 x 1 minute
Maximum permissible operating current 1.8 x In
Maximum peak inrush current 400 xIn
Capacity tolerance + / – 5 %
Power loss < 0.20 W / kvar, without discharge resistors
Voltage test
(clamp – clamp)
2.15 x Unenn (AC), 10 sec
Voltage test
(terminal – housing)
≤ 690 V : 3600 V (AC), 2.5 sec
> 690 V : 6000 V (AC), 10 sec – according to standard
Cooling Self-cooling
Permissible humidity 95 %
Maximum insert height 4000 m above sea level
Installation location, installation position inside, any
Fastening M12 threaded bolt on the floor
Security features – Dry technology, resin-filled
– Self-healing
– All-pole overpressure shut-off protection
– SF6-free, PCB-free
Housing Aluminum
Protection class IP 20
Dielectric Polypropylene
Connection terminals Finger-safe, double-sided connection terminal
Discharge Discharge resistors external to the terminal
Standards IEC 60831-1 + 2, EN 60831-1 + 2,
VDE 0560-46 + 47
multicond premium UHPC and multicond UHPC multicond basic UHPC multicond light UHPC
Power capacitors multicond temperature class D and 5
Temperature class D+5
-40/60
> 150000 h
max. ambient temperature: 60°C
max. 24 h average value: 50°C
max. Annual average: 40°C
Power capacitors multicond temperature class D 250000h Power capacitors multicond temperature class D 130000h Power capacitors multicond temperature class D 100000h
Temperature class D
-40/55
Temperature class D
-40/55
Temperature class D
-40/55
Life expectancy*
> 250000 h
max. ambient temperature: 55°C
max. 24 h average value: 45°C
max. Annual average: 35°C
Life expectancy*
> 130000 h
max. ambient temperature: 55°C
max. 24 h average value: 45°C
max. Annual average: 35°C
Life expectancy*
> 100000 h
max. ambient temperature: 55°C
max. 24 h average value: 45°C
max. Annual average: 35°C
Power capacitors multicond temperature class C 150000h Power capacitors multicond temperature class C 130000h
Temperature class C
-40/50
Temperature class C
-40/50
Life expectancy*
> 150000 h
max. ambient temperature: 50°C
max. 24 h average value: 40°C
max. Annual average: 30°C
Life expectancy*
> 130000 h
max. ambient temperature: 50°C
max. 24 h average value: 40°C
max. Annual average: 30°C

 

*The maximum life expectancy depends on the type of application and the temperature class

Storage conditions for power capacitors multicond:
min / max Temp: -40 – + 85°C
Max humidity: <95% without condensation Do not store in corrosive and aerosol-containing atmospheres, especially if chloride gas, sulphur compounds, salts (sea air) or similar are present.

Fittingly:
multimod-f-050-01-14-steck_

Plug-in module plug-in technology

multiind-drossel_

Filter circuit chokes

KBR
Support Team

We are happy to arrange
the contact to our
references and are available for
available for an interview.

Just get in touch with us.
Phone: +49 9122 6373-0
E-mail: info@kbr.de

Tablet mit Screenshot

Download

More information (brochures, user manuals, etc.) under download.